Menu

2803522 - Phoenix Contact Surge Protection Device

Type 2 surge protection device Surge arrester for 4-conductor power supply systems (L1, L2, L3, PEN), consisting of a base element and protective connectors, for mounting on NS 35.


Part #: 2803522
$184.74Order Details
Availability:
Out of Stock

Phoenix Contact Surge Protection Device

Color: Black
Material: PBT, PA
Connecting Thread: M5
Type: 2, DIN Rail Module
Positions: 3
Protection Level: IP20
Nominal Voltage: 230 VAC
Connection: Screw Connection
Product Type: Surge Protection Device
  • Connection, protective circuit
    Conductor cross section AWG/kcmil max: 2
    Conductor cross section AWG/kcmil min.: 15
    Conductor cross section solid max.: 35 mm²
    Conductor cross section solid min.: 1.5 mm²
    Conductor cross section stranded max.: 25 mm²
    Conductor cross section stranded min.: 1.5 mm²
    Connection method: Screw connection
    Connection type IN: Biconnect screw terminal block
    Connection type OUT: Biconnect screw terminal block
    Screw thread: M5
    Stripping length: 16 mm
    Tightening torque: 4.5 Nm
  • Protective circuit
    Arrester rated voltage U<sub>C</sub>: 350 V AC
    Arrester rated voltage U<sub>C</sub> (L-PEN): 350 V AC
    EN type: T2
    Ground conductor current I<sub>PE</sub>: ? 340 µA (Per phase)
    IEC category: II
    IEC category: T2
    Max. discharge surge current Imax (8/20) µs: 20 kA (per channel L-PEN)
    Max. discharge surge current Imax (8/20) µs maximum (L-PEN): 60 kA (all channels)
    Max. discharge surge current Imax (8/20) µs maximum (L-PEN): 20 kA (per channel)
    Max. required backup fuse with branch wiring: 125 A (gL/gG)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-PEN): 30 kA (all channels)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-PEN): 10 kA (per channel)
    Nominal frequency f<sub>N</sub>: 50 Hz (60 Hz)
    Nominal voltage U<sub>N</sub>: 230 V AC (400 V AC)
    Nominal voltage U<sub>N</sub>: 230 V AC (400 V AC)
    Protection level U<sub>P</sub> (L-PEN): ? 1.4 kV
    Residual voltage (L-PEN): ? 1.4 kV
    Residual voltage (L-PEN): ? 1.2 kV (at 5 kA)
    Residual voltage (L-PEN): ? 1.1 kV (at 3 kA)
    Response time (L-N): ? 25 ns
    Short-circuit resistance I<sub>P</sub> with max. backup fuse (effective): 25 kA
    Standby power consumption P<sub>C</sub>: ? 360 mVA
    U<sub>T</sub> (TOV-proof): 415 V AC (5 s)
  • Standards
    Ambient temperature (operation): -40 °C ... 80 °C
    Color: black
    Degree of protection: IP20
    Depth: 65.5 mm
    Design: DIN rail module, two-section, divisible
    Direction of action: 3L-PEN
    Height: 90 mm
    Housing material: PBT / PA
    Inflammability class according to UL 94: V0
    Message: Surge protection fault: Optical
    Mounting type: DIN rail: 35 mm
    Number of positions: 3
    Pitch unit: 3 Div.
    Standards for air and creepage distances: EN 60664-1
    Standards for air and creepage distances: EN 61643-11
    Standards/regulations: IEC 61643-1 2005
    Width: 53.4 mm
Email this page to a friend
Part Number Tags: N/A

This part number has been discontinued by {Manufacturer}. Use the contact form below to find out the new compatible part.

Updating...